05 primary power connections, Primary power connections -5, Auto-cut 200 xt – Tweco 200 XT Auto-Cut 380V User Manual

Page 29

Advertising
background image

AUTO-CUT 200 XT

Manual 0-5253

INSTALLATION

3-5

3.05 Primary Power Connections

The primary power cable and through hole cable grip must be supplied by the end user and connected to the power

supply. Refer to local and national electrical codes for suggested cable and fuse sizes.

Remove the left side covers of the Power Supply.

Connect Input Power and System Ground Cables

1. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut back

the insulation on the individual wires. Route the cable through the rear panel of the power supply.

2. Insert the individual wires into the proper terminals on the contactor as shown. There are factory installed wires

already attached to these same terminals and will need to be loosened first. Do Not remove these wires. Tighten

the screws onto both sets of wires using a 4mm hex key wrench.

Art # A-11550

4mm

3. Connect the input power cable ground wire to the ground terminal block as shown above.

4. Connect a system ground cable (F1) to the ground terminal on the outside of the power supply located next to

the Torch Leads port. Refer to the Ground Connections Section for full details and procedures on proper system

grounding.

Advertising