AUTO-CUT 200 XT

�-�

OPERATION

Manual 0-5253

11. Shut off the system.

a. Set the ON/OFF power switch on the front panel of the unit to OFF.

Warning!

AC power is still present inside the unit.

• Fans and pump as well as all indicators turn off.
• The display may show a fault code for a moment, this is a normal part of shutting off power and does not

indicate a fault.

b. Open (turn off) the main power disconnect. All power is now removed from the unit.

• Rear panel AC indicator turns OFF.

Operational Suggestions

1. Wait four minutes before setting the ON/OFF switch to OFF after operation. This allows the cooling fans to run

to dissipate operating heat from the power supply.

2. For maximum parts life, do not operate the pilot arc any longer than necessary.

3. Use care in handling torch leads and protect them from damage.

4. When using water as the shield note the following:

• Use clean drinking quality tap water to help prevent particulate build-up within the system water shield

plumbing.

• Particulate contamination and build-up can cause reduced consumable parts life and premature torch failure.

• A cartridge type particulate water filter may help achieve optimum cutting performance.