Arcmaster, 160ts – Tweco 160 TS Arcmaster User Manual
Page 27

ARCMASTER
®
160TS
March 31, 2006
3-5
3.04 Weld Parameters for ArcMaster 160TS
Weld Mode
Weld
Parameter
Parameter Range
Factory
Setting
Incremental
Unit
STICK
HF
TIG
LIFT TIG
PRE-FLOW
0.0 to 1.0 sec
0.1 sec
0.1 sec
No
Yes
Yes
HOT START
0 to 70A
20A
1A
Yes
Yes
No
INITIAL CUR.
1 to 160A
30A
1A
No
Yes
Yes
UP SLOPE
0 to 15 sec
1 sec
0.1 sec
No
Yes
Yes
PEAK CUR.
1 to 160A
120A
1A
No
Yes
Yes
WELD CUR
1 to 160A 230V
1 to 85A 115V
80A
80A
1A
1A
Yes
Yes
Yes
Yes
Yes
Yes
SPOT TIME
0.5 to 5.0 sec
2 sec
0.1 sec
No
Yes
No
PULSE WIDTH
15 to 80%
50%
1%
No
Yes
Yes
PULSE FREQ.
0.5 to 500Hz
100.0Hz
See Table 6
No
Yes
Yes
DOWN SLOPE
0 to 25 sec
3 sec
0.1 sec
No
Yes
Yes
CRATER CUR.
1 to 160A
30A
1A
No
Yes
Yes
POST-FLOW
0.0 to 60 sec
10 sec
0.1 sec
No
Yes
Yes
Table 5 – Weld Parameters for ArcMaster 160TS
PULSE FREQ. Range
Incremental Unit
0.5 to 20Hz
0.1Hz
20 to 100Hz
1Hz
100 to 500Hz
5Hz
Table 6 – PULSE FREQ. Range and Incremental Units