Arcmaster, 160ts – Tweco 160 TS Arcmaster User Manual

Page 49

Advertising
background image

ARCMASTER

®

160TS

March 31, 2006

11-1

SECTION 11:

POWER SOURCE ERROR CODES

Description

P

ossible Cause

Remedy

Remarks

1

E01 error code displayed

Tempera

ture sensor

TH1 (protects IGBTs)

is grea

ter than 80ºC for about 1 second

A

B

C

The

W

elding P

o

wer Source’

s duty

cyc

le has been exceeded.

Fan ceases to opera

te.

Air fl

o

w is restricted by vents

being blocked.

A

B

C

Let P

o

wer Source cool do

wn

then keep within its duty c

yc

le.

Ha

ve

an Accredited Thermal Arc

Ser

vice Agent

investiga

te.

Unblock vents then let P

o

wer

Source cool do

wn.

W

eld current ceases.

Buzzer sounds constantly

.

E01 resets when

TH1 decreases

to 70ºC for about 30 seconds.

2

E03 error code displayed

Primar

y (input) current too high

A

B

Primar

y current is too high

because welding arc is too long.

Mains supply volta

ge is more

than 10% belo

w nominal volta

ge

.

A

B

Reduce length of welding arc.

Ha

ve

an Accredited Thermal

Arc Ser

vice

Agent or a qualifi

ed

electrician check for lo

w Mains

volta

ge.

W

eld current ceases.

Buzzer sounds constantly

.

Switch machine off then on to

reset E03 error

.

3

E11 error code displayed

Over Primar

y supply (input) volta

ge a

t

primar

y ca

pacitors is exceeded for one

second

Primar

y supply volta

ge is grea

ter

than the nominal volta

ge plus

10%.

Ha

ve

an Accredited Thermal

Arc Ser

vice

Agent or a qualifi

ed

electrician check the Primar

y

volta

ge.

W

eld current ceases.

Buzzer sounds constantly

.

Error code E11 automa

tically will

reset when the volta

ge reduces.

4

E12 error code displayed

Under mains supply (input) volta

ge

primar

y ca

pacitors is reduced for one

second

Mains supply volta

ge is do

wn to

a dangerously lo

w level.

A

B

Ha

ve

an Accredited Thermal

Arc Ser

vice

Agent or a qualifi

ed

electrician check the Mains

volta

ge.

Ha

ve

an Accredited Thermal

Arc Ser

vice

Agent or a qualifi

ed

electrician check the primar

y

cable & fuses.

W

eld current ceases.

Buzzer sounds constantly

.

Error code E12 automa

tically

will reset when the volta

ge

increases.

5

E93 error code displayed

Memor

y chip (EEPROM) on control PCB

can not read/write weld parameters

Memor

y chip (EEPROM) error

.

Ha

ve an

Accredited

Thermal

Arc

Ser

vice

Agent check the control

PCB.

W

eld current ceases.

Buzzer sounds constantly

.

Switch machine off.

6

E94 error code displayed

Tempera

ture sensor

TH1 for IGBT’

s is an

open circuit.

The

W

elding P

o

wer Source’

s

tempera

ture sensors ha

ve

malfunctioned.

Ha

ve

an Accredited Thermal Arc

Ser

vice

Agent check or replace

the tempera

ture sensors.

W

eld current ceases.

Buzzer sounds constantly

.

Switch machine off.

Advertising