10-1

SECTION 10:

VOLTAGE REDUCTION DEVICE (VRD)

10.01 VRD Specifi cation

Description

ArcMaster 160TS

Notes

VRD Open Circuit Voltage

15.3 to 19.8V

Open circuit voltage between welding terminals

VRD Resistance

148 to 193 ohms

The required resistance between welding
terminals to turn ON the welding power

VRD Turn OFF Time

0.2 to 0.3 seconds

The time taken to turn OFF the welding power
once the welding current has stopped

10.02 VRD Maintenance

Routine inspection and testing (power source)

An inspection of the power source, an insulation resistance test and an earth resistance test shall be carried out.

a) For transportable equipment, at least once every 3 months; and

b) For fixed equipment, at least once every 12 months.

The owners of the equipment shall keep a suitable record of the periodic tests.

NOTE

A transportable power source is any equipment that is not permanently connected and fi xed in the position in
which it is operated.

In addition to the above tests and specifi cally in relation to the VRD fi tted to this machine, the following periodic tests should
also be conducted by an accredited Thermal Arc service agent.

Description

IEC 60974-1 Requirements

VRD Open Circuit Voltage

Less than 20V; at Vin=115V or 230V

VRD Turn ON Resistance

Less than 200 ohms

VRD Turn OFF Time

Less than 0.3 seconds

If this equipment is used in a location or environment with a high risk of electrocution then the above tests should be carried
out prior to entering this location.