Tweco 2460 Heavy Duty CC CV Control Wire Feeder User Manual
Page 57

10/7/2002 Revised
5
LEGEND
L1
J1-6
B1
S2
J3-1
J1-1
GAS VALVE
P.C. BOARD
B1
CR1
F1
F2
J1
J2
J3
R1
S1
J4
S2
TB1
L1
GAS VALVE, 12VDC
TERMINAL BLOCK
SWITCH, CC/CV
RECEPTACLE, GUN SWITCH
SWITCH, ON-OFF
POTENTIOMETER, 10KOHMS, 2W
RECEPTACLE, MOTOR CONTROL BOARD
RECEPTACLE, METER OPTION
RECEPTACLE, MOTOR CONTROL BOARD,
FUSE, SLOW BLOW, 5A
FUSE, SLOW BLOW, 7A
RECTIFIER, BRIDGE
MOTOR, WIRE FEED
J1-9
J1-10
J1-12
J1-11
J2-1
J2-3
F2
MOTOR CONTROL
P.C. BOARD
J1-3
J3-2
J1-5
J3-3
J1-2
J3-4
J1-4
GAS VALVE BOARD
DIAGRAM, CONNECTION & SCHEMATIC
2460 HEAVY DUTY WIRE FEEDER
NONE
2
FULL
TLT
JLC
6-6-97
376784B2
11-6-97
TLT
TLT
8-15-91
150
8-91
TECH PUB
376784B
CHANGE RECORD
E.C. No.
DATE
PLOT DATE
CHECKED
APPROVED
RECORDS
ITEM TYPE
DESIGNED
DRAWN
DATE
SCALE
COMM. CLS.
DESCRIPTIVE DATA
TITLE
MATERIAL SPEC.
MATERIAL NO.
ACTIVITY
FINISH CODE PER
REPLACED BY
REPLACES
QUANTITY-U.M.
DWG. NO.
SIZE
C
FRACT.
INCH
±
SHEET
FILE NAME
1
2
3
4
DISTRIBUTION TABLE
OUTSIDE DISTR.
A
B
C
D
E
F
4
3
2
1
CONFIDENTIAL: This drawing, including all information
contained thereon, is the exclusive and confidential property of
Thermal Arc Corporation of Troy, Ohio 45373 . This drawing is
not to be copied, reproduced, delivered or disclosed to others,
in whole or in part, except with express written permission.
TROY, OHIO 45373, U.S.A.
ANGLES
± 3˚
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES/MILLIMETERS
TOLERANCES BELOW APPLY EXCEPT FOR
VENDOR DESIGNED PARTS AND ITEMS.
PRODUCED TO RECOGNIZED STANDARDS.
DECIMAL-INCH
0.00 ± 0.1mm
0.0 ± 0.4mm
0. ± 1.0mm
.000 ± .003
.00 ± .02
DO NOT SCALE DRAWING
.0 ± .1
A THERMADYNE Company
R
R