04 basic parts replacement – Tweco CE Ultima 150 User Manual

Page 34

Advertising
background image

SECTION 5: GENERAL MAINTENANCE

28

Manual 0-2530

G. Welding Problems

See the appropriate torch manual for torch troubleshoot-
ing.

5.04 Basic Parts Replacement

The parts replacement procedures described in this
manual are for basic replacement of parts that require lim-
ited or no disassembly of the unit. This section describes
parts replacement for the following:

1. Fuse Replacement

2. Coolant Filter Assembly Replacement

3. In-line Filter Replacement

4. Hose Assembly Replacement

For parts that require more complex disassembly, see the
ULTIMA-150 Service Manual No. 0-2503.

Before disassembling any part of the ULTIMA-150 Plasma
Welding Power Supply, first read the procedure for the
part to be replaced, then proceed with the disassembly.

WARNING

Disconnect primary power from the source before
disassembling or replacing parts on the ULTIMA-
150 Plasma Welding Power Supply.

A

Opening the ULTIMA-150 Power Supply

1. Remove the four Phillips head screws on the top of

the Enclosure Cover.

2. Loosen the six Phillips head screws, three on each

side, at the bottom edge of the Enclosure Cover.

3. Carefully pull the Enclosure Cover up from the

rest of the unit.

B. Fuse Replacement

1. Remove the Enclosure Cover per Section 5.04.

2. Locate the Fuse on the side of the chassis above the

Front Panel Breaker Assembly.

3. Remove the Fuse.

4. Install replacement Fuse by reversing the above

AC Input Cable

Fuse

Primary
Power Switch

A00810

Figure 5-6 Fuse Location

C. Coolant Filter Assembly Replacement

The Coolant Filter Assembly is located on a bracket on
the rear panel of the unit.

1. Remove the two coolant hose connections to the

Filter Assembly.

2. Remove the two elbow fitting on each side of

the Coolant Filter Assembly and remove the
damaged Coolant Filter Assembly from the
bracket.

Advertising