Recommended Circuit Protection and Wire Sizes

Input

Power Input

Current

Recommended Sizes

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

380

50/60

6

12

15

14

415

50/60

6

12

15

14

Line Voltages with Recommended Circuit Protection and Wire Sizes (Based on Table

310-16, 1987 National Electric Code) and Table 4, Canadian Electrical Code.

NOTES

An energy-limiting fuse UL Class RK-1 (examples: BUSS LPS/
LPN-RK or Gould-Shawmut AZK-A6K) should be used to mini-
mize damage to plasma welding, plasma cutting, and power distri-
bution equipment.

NEVER use replaceable element fuses like UL Class H, or "one-
time" fuses like UL Class K5.