Appendix iii: remote wiring – Tweco CE Ultima 150 User Manual

Page 43

Advertising
background image

Manual 0-2530

37

APPENDICES

APPENDIX III: REMOTE WIRING

Notes:

1. Welding Arc/ON disabled without clos-

ing TB1-3 to TB1-4. This must be done
by direct interface to TB1-3 & TB1-4 or
via remote connection J20 Pin 3 to 4.

2. To disable the pilot arc when coolant con-

ductivity level is high, connect pin 12
to pin 24 and pin 13 to pin 23.

3. Weld Arc On Detect (for use with

Synerweld 2100) is enabled with the
following wiring connections*:

• TB1-6 to J20 pin 11

• TB1-7 to J20 pin 12

(If not using J20, wire directly from in-
put/output interface signals to TB1.)

* Ultima units manufactured after Nov.
1997 are factory-wired; all other units
must be wired by user.

4. Wiring Connections for the 3A Torch

with Auto Wire Feed are through J20 to
Quick Disconnect.

TB1

Quick
Disconnect

J20

A-00830

Rear Panel View

A-00831

OUTPUTS INPUTS

11
12

2

5
6

Quick

Disconnect

1
2

6

Advertising