03 cleaning the welding power source, Cleaning the welding power source -5, Factory reset -5 – Tweco 170Pi Transtig User Manual

Page 60: Transtig 170pi

Advertising
background image

TRANSTIG 170Pi

POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS 5-4 Manual 0-5241

F. Accessories

Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be

inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable

condition. All unsafe accessories shall not be used.

G. Repairs

If any parts are damaged for any reason, it is recommended that replacement be performed by an ac-

credited Cigweld Service Provider.

Power Source Calibration

A. Schedule

Output testing of all Cigweld Inverter Power Sources and applicable accessories shall be conducted at

regular intervals to ensure they fall within specified levels. Calibration intervals shall be as outlined below -

1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.

If equipment is to be used in a hazardous location or environments with a high risk of electrocution as

outlined in AS 1674.2 - 2007, then the above tests should be carried out prior to entering this location.

B. Calibration Requirements

Where applicable, the tests outlined in Table 6-3 below shall be conducted by an accredited CIGWELD

service agent.

Testing Requirements

Output current (A) to be checked to ensure it falls within applicable Cigweld power source specifications
Output Voltage (V) to be checked to ensure it falls within applicable Cigweld power source specifications
Accuracy of digital meters to be checked to ensure it falls within applicable Cigweld power source specifi-

cations

Table 5-4: Calibration Parameters

Periodic calibration of other parameters such as timing functions are not required unless a specific fault

has been identified.

C. Calibration Equipment

All equipment used for Power Source calibration shall be in proper working condition and be suitable for

conducting the measurement in question. Only test equipment with valid calibration certificates (NATA

certified laboratories) shall be utilized.