03 routine service and calibration requirements, 02 routine service and calibration requirements, Routine service and calibration requirements -2 – Tweco 200DC Inverter Arc Welding Machine User Manual

Page 56: Weldskill 200ac/dc inverter

Advertising
background image

WELDSKILL 200AC/DC INVERTER

POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS 5-2 Manual 0-5207

5.03 Routine Service and Calibration Requirements

!

WARNING

There are extremely dangerous voltage and power levels present inside this Inverter Power Source.

Do not attempt to open or repair unless you are an accredited CIGWELD Service Provider. Discon-

nect the Welding Power Source from the Mains Supply Voltage before disassembling.

Routine Inspection, Testing & Maintenance
The inspection and testing of the power source and associated accessories shall be carried out in accordance

with Section 5 of AS 1674.2 - 2007: Safety in Welding and Allied Processes-Part 2 Electrical. This includes an

insulation resistance test and an earthing test to ensure the integrity of the unit is compliant with CIGWELD

original specifications.
If equipment is to be used in a hazardous location or environments with a high risk of electrocution as outlined

in AS 1674.2 - 2007, then the above tests should be carried out prior to entering this location.

A. Testing Schedule

1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.

The owners of the equipment shall keep a suitable record of the periodic tests and a system of tagging,

including the date of the most recent inspection.

A transportable power source is deemed to be any equipment that is not permanently connected and fixed

in the position in which it is operated.

B. Insulation Resistance

Minimum insulation resistance for in-service CIGWELD Inverter Power Sources shall be measured at a

voltage of 500V between the parts referred to in Table 5-2 below. Power sources that do not meet the

insulation resistance requirements set out below shall be withdrawn from service and not returned until

repairs have been performed such that the requirements outlined below are met.

Components to be Tested

Minimum Insulation

Resistance (MΩ)

Input circuit (including any connected control circuits) to welding circuit

(including any connected control circuits)

5

All circuits to exposed conductive parts

2.5

Welding circuit (including any connected control circuits) to any auxiliary

circuit which operates at a voltage exceeding extra low voltage

10

Welding circuit (including any connected control circuits) to any auxiliary

circuit which operates at a voltage not exceeding extra low voltage

1

Separate welding circuit to separate welding circuit

1

Table 5-2: Minimum Insulation Resistance Requirements: CIGWELD Inverter Power Sources

C. Earthing

The resistance shall not exceed 1Ω between any metal of a power source where such metal is required

to be earthed, and -

1. The earth terminal of a fixed power source; or
2. The earth terminal of the associated plug of a transportable power source

Advertising
This manual is related to the following products: