Transtig 300pi – Tweco 300Pi Transtig Welding Inverter User Manual

Page 31

Advertising
background image

TRANSTIG 300Pi

Manual 0-5309

3-13

INSTALLATION, OPERATION AND SETUP

Pulse Width

This parameter sets the percentage

“on” time of the PULSE FREQUENCY

for BASE weld current when in DC

PULSE operating mode.
Range is 15 to 80%. Factory default

is 50%.

(Pulse)

A-12109

Pulse Frequency

This parameter sets the PULSE

FREQUENCY when in DC PULSE

operating mode.
Range is 0.5 to 500Hz. Factory default

is 100Hz.

(Pulse)

A-12110

Down Slope

This parameter operates in TIG modes

only and is used to set the time for

the weld current to ramp down to the

crater current. This control is used to

eliminate the crater that can form at

the completion of a weld.
Range is 0.0 to 25.0 seconds. Factory

default is 3.0 seconds.

(Pulse)

A-12111

Advertising