TRANSTIG 300Pi

Manual 0-5309

3-19

INSTALLATION, OPERATION AND SETUP

Shutdown

Close cylinder valve whenever the regulator is not in use. To shut down for extended periods (more than 30

minutes).

1. Close cylinder or upstream valve tightly.
2. Open downstream equipment valves to drain the lines. Bleed gas into a well ventilated area and away

from any ignition source.

3. After gas is drained completely, disengage adjusting screw and close downstream equipment valves.
4. Before transporting cylinders that are not secured on a cart designed for such purposes, remove

regulators.

3.11 Foot Control Part No. W4015800 (Optional Accessory)

Art # A-11338

Figure 3-11: Foot Control

Art # A-11339

1

2

3

4

5

6

7

8

Art # A-11340

Figure 3-12: 8 Pin Control Plug

Pin

Description

1

Not Used

2

Trigger Switch

3

Trigger Switch

4

Not Used

5

Potentiometer Maximum

6

Potentiometer Minimum

7

Potentiometer Wiper

8

Not Used

Table 3-3

Description
The CIGWELD Foot Control is a foot operated switch and potentiometer which starts and stops the welding

process and controls welding current through operation of the foot pedal. Refer to list below for compatible

Cigweld power sources.