Section 11: basic troubleshooting, Proplus auto-darkening welding helmets – Tweco ProPlus Digital Auto-Darkening Welding Helmet User Manual

Page 23

Advertising
background image

ProPlus Auto-Darkening Welding Helmets

Manual 0-5276

23

SECTION 11: Basic Troubleshooting

FAUlT

CAUSE

REMEDY

1. Irregular darkening dimming.

A.

Headband has been set unevenly

and there is an uneven distance

from the eyes to the filter lens.

A.

Reset the headband to reduce the

difference to the filter

2. Auto-Darkening filter does not

darken or flickers.

A.

B.

C.

Front cover lens is soiled or

damaged.

Sensors are soiled.

Welding current is too low.

A.

B.

C.

D.

E.

Clean Cover Lens with a soft cloth.

Replace if necessary.

Clean the sensors surface.

Adjust the sensitivity level to higher.

Check battery and verify they are in

good condition and installed properly.

Also, check battery surfaces and

contacts and clean if necessary.

Make sure “ON/MODE” button has

been pushed, the user can monitor

the settings from the display panel.

3. Slow response.

A.

Operating temperature is too low.

A.

Do not use at temperatures below

-10º C.

4. Poor vision.

A.

B.

C.

Front/inside cover lens and/or the

filter are soiled.

There is insufficient ambient light.

Shade number is incorrectly set.

A.

B.

Change lens.

Reset the shade number.

5

Welding helmet slips.

A.

Headband is not properly

adjusted.

A.

Readjust the headband.

Table 11-1 Basic Troubleshooting

!