05 general, 05 general -3, Transmig vs 212 – Tweco VS212 Wire Feeder User Manual

Page 15

Advertising
background image

TRANSMIG VS 212

Manual No. 0-4949

2-3

INTRODUCTION

2.05 General

The TRANSMIG VS 212 is a portable, solid state
controlled, voltage sensing wire feeder that operates
on arc voltage and can be used with most constant
voltage (CV) and constant current (CC) DC-type power
sources. The only connection required between the
power source and the wire feeder is the welding cable.

The unique design of this wire feeder allows operation
in a constant wire feed speed mode when used with
CV power sources, and in a voltage sensing wire feed
speed mode (wire feed speed varies with respect to
arc voltage) when used with CC power sources.

The TRANSMIG VS 212’s steel-reinforced, flame-
retardant case totally encloses the solid state control
circuitry, welding wire, and wire drive system. A
hinged, latched door allows quick and easy access to
the contactor, welding wire, and feedhead assembly
that features quick change, gear-driven drive rolls.

TRANSMIG VS 212 comes with:

• Robust injection molded case

• Changeable MIG gun cartridge system

• Heavy duty contactor

• Internal parts storage

• Power cable and drive rolls

• Gas valve solenoid

The TRANSMIG VS 212, includes the following
features:

1. An on/off rocker switch

2. A wire feed speed control knob

3. A welding gun holder

4. A carrying handle

5. A contactor

6. A gas valve

7. A CC/CV mode switch

8. An input circuit breaker for complete system

protection

9. An electronic controlled protection circuitry to

protect against an undervoltage, an overvoltage,
a voltage spike, a shorted or locked motor, a
shorted contactor coil, and a shorted gas valve

10. An electronic controlled dynamic brake

11. An electronic controlled current limit to motor

12. An electronic controlled start circuit for improved

arc starting

13. A low voltage gun trigger circuit for operator safety

14. A drive roll kit

15. In addition to these standard features, the

Transmig VS212 also includes a digital display for
wire feed speed/amps and arc voltage, with arc
time and memory hold.

16. Trigger Hold Switch

The TRANSMIG VS 212 has been designed to comply
with IEC 60974-1 (CE), CSA NRTL/C, and NEMA EW
3 standards.

Advertising