Transmig 200i, 09 duty cycle – Tweco 200i Multi Process Welding Inverter User Manual

Page 16

Advertising
background image

TRANSMIG 200i

INTRODUCTION

2-4

Manual 0-5209

2.09 Duty Cycle

The rated duty cycle of a Welding Power Source, is a statement of the time it may be operated at its rated

welding current output without exceeding the temperature limits of the insulation of the component parts. To

explain the 10 minute duty cycle period the following example is used. Suppose a Welding Power Source is

designed to operate at a 20% duty cycle, 210 amperes at 24.5 volts. This means that it has been designed

and built to provide the rated amperage (210A) for 2 minutes, i.e. arc welding time, out of every 10 minute

period (20% of 10 minutes is 2 minutes). During the other 8 minutes of the 10 minute period the Welding

Power Source must idle and allowed to cool. The thermal cut out will operate if the duty cycle is exceeded.

10

20

30

40

50

60

70

80

90 100 110 120 130 140 150 160 170 180 190 200 210 220

TRANSMIG 200i

Welding Current (AMPS)

SAFE OPERATING REGION

(MIG, TIG & STICK)

0

0

10

20

30

40

60

70

50

80

100

90

Duty Cycle (PERCENTAGE)

MIG

STICK / TIG

Art # A-10438

Figure 2-1: Transmig 200i Duty Cycle

Advertising