Transmig 200i, 10 inserting wire into the wire feed mechanism – Tweco 200i Multi Process Welding Inverter User Manual

Page 31

Advertising
background image

TRANSMIG 200i

Manual 0-5209

3-13

INSTALLATION, OPERATION AND SETUP

3.10 Inserting Wire into the Wire Feed Mechanism

Release the tension from the pressure roller by turning the adjustable wire drive tension screw in an anti-

clockwise direction. Then to release the pressure roller arm push the tension screw toward the front of the

machine which releases the pressure roller arm (Figure 3-8). With the MIG welding wire feeding from the

bottom of the spool (Figure 3-9) pass the electrode wire through the inlet guide, between the rollers, through

the outlet guide and into the MIG torch. Re-secure the pressure roller arm and wire drive tension screw and

adjust the pressure accordingly (Figure 3-8). Remove the contact tip from the MIG torch. With the MIG Torch

lead reasonably straight, feed the wire through the torch by depressing the trigger switch. Fit the appropriate

contact tip.

WARNING

Before connecting the work clamp to the work make sure the mains power supply is switched

off.
The electrode wire will be at welding voltage potential while it is being feed through the system.
Keep Mig Torch away from eyes and face.

Wire Drive Tension Screw

Pressure Roller Arm

Outlet Guide

Inlet Guide

Art # A-10426

Figure 3-8: Wire Drive Assembly Components

Mig Welding Wire

Art # A-10427

Figure 3-9: Mig Welding Wire - Installation

Advertising