2. Assembly
Important: To make assembly process as convenient as possible, use of a lift crane or some
other equipment for lifting the lower tube of the auger is recommended. Support
discharge end of auger to prevent upending.
2.1. TUBE CLAMPS AND TRANSITION FLIGHT ASSEMBLY
Figure 2.1
1. For Retrofits: First remove existing flighting guard and transition flighting.
2. Connect
top
and
bottom tube clamp on lower tube with twelve 7/16" x 1-1/4"
bolts and locknuts, tighten securely.
Note:
Line tube clamp flange flush with end of lower tube.