Confirm system operation, Closeout, Steering system operation – Great Plains EHPR Valve Calibration User Manual

Page 5: Caution

Advertising
background image

Great Plains Mfg., Inc.

Calibration Procedure

5

12/10/2008

401-565M

Confirm System Operation

Leave the fan/steering circuit active for these steps.

26. Disconnect the HHCT from the ECU.

!

CAUTION

Injury Risk:

Be directly ahead or behind, and outside a caster wheel for
step 27
through step 29. At one or more steps the caster wheels
are likely to pivot under hydraulic power to match the current
tractor steering direction. This movement is sudden and force-
ful, and could knock you down or crush you if you get between
the wheel and nearby planter components.

27. Spin the left caster wheel forward. The fan should

engage, and manual pivoting of the casters should
be possible.

28. Stop the wheel. This may stop the fan. It may or may

not be possible to manually pivot the caster.

29. Spin the left caster wheel backwards. The fan should

stop/not engage. The casters may pivot to match
tractor steering - this could be a small or a large
movement. It should not be possible to manually
pivot the casters, as it they are now under active
hydraulic control.

Closeout

30. Set the fan/steering hydraulic circuit control to Float.

31. At the steering console, set the REVERSE STEER

switch OFF (down).

32. Lower the seed cart to the ground.

33. Perform Parking checklist from Operator Manual.

Steering System Operation

See Operator Manual 401-312M.

Advertising