Install Sensor

Refer to Figure 14 (this example depicts the 2S-2600)
4.

Select one each new:

168-491D ACREMETER SWITCH MOUNT

221398 SWITCH

and two sets new:

804-036C WASHER FLAT 5/16 SAE PLT

801-067C SCREW RD HD 8-32 X 1 1/2LG PLT

804-043C WASHER LOCK #8

803-064C NUT HEX 8-32

and four new:

804-088C WASHER FLAT #8 SAE PLT

5.

Mount the u-shaped face of the switch mount

to

the face of the bearing flangette using the existing
flange bolts

, new flat washers

and existing

flange nuts

.

6.

Attach the flat face of the switch mount

(part

facing the sensor) using the screws

, flat

washers

, lock washers

and hex nuts

.

7.

Attach the pickup sensor to the sensor bracket.
Secure the ground wire to one of the mounting
screws. Slide the sensor so it is no more than

1

8

inch

from the magnet actuator. Do not allow the sensor to
touch the magnet actuator.
Leave screws finger tight
until Step 9.

Note: The individual wire

on the sensor is a frame

ground wire that is designed to protect the acre
counter from any static discharge that it may
encounter. It should be attached to the metal on
the drill somewhere.