1

Installation Instructions

Great Plains Mfg., Inc.

© Copyright 1998 Printed 4/8/04

Used with:


507-095M

Application Systems

PTO Sprayer Pump

3P300

TA500

General Information

These instructions explain how to install the Application Systems
PTO pump. The pump pressurizes sprayer contents for applica-
tion.

These instructions apply to:

507-041A

PUMP TA 540 DRIVE SHAFT ASSY

507-042A

PUMP TA 1000 1 3/8 DRV SHAFT

507-051A

PUMP 3-POINT 540 ASSY

507-052A

PUMP 3-POINT 1000 1-3/8 ASSY

Manual Update

Refer to the operator’s manual for detailed information on safely
operating, adjusting, troubleshooting and maintaining the Appli-
cation Systems PTO pump. Refer to the parts manual for part
identification.

• 3P300 Operator’s Manual . . . . . . . . . . . . . . . . . . .500-103M

• 3P300 Parts Manual. . . . . . . . . . . . . . . . . . . . . . . . 500-062P

• TA500 Operator’s Manual. . . . . . . . . . . . . . . . . . . .500-102M

• TA500 Parts Manual. . . . . . . . . . . . . . . . . . . . . . . . 500-061P

Before You Start

Beginning on page 3 are detailed listings of parts included in the
Application Systems PTO pump packages. Use these lists to in-
ventory parts received.

Assembly Instructions

TA500 Assembly

Refer to Figure 1

1.

Attach driveline-bearing mount (1) to sprayer tongue (2) us-

ing 3/8-inch bolts and flange nuts.

2.

Mount pump (3) onto output shaft of driveline-bearing

mount. Secure shaft coupler (4) with 1/2-inch bolts and ny-

lock nuts.

3.

Mount torque arm (5) on pump using 5/16-inch car-
riage bolts and flange nuts.

4.

Thread set screws (6) into yoke of PTO shaft and

install key (7) into input shaft of bearing mount.

Slide PTO shaft onto

input

shaft and

tighten

set screws.

5.

Install 1-

inch hose (8)

between pump

outlet and Whirlfilter

inlet. Secure with worm

clamps.

6.

Cut 1 1/2-inch hose into a 6-

inch-long section and a 45-

inch-long section.

7.

Using 1 1/4-by-1 1/2-inch elbow (9), install 6-inch
section of hose (10) onto pump inlet. Install 1 1/2-
inch elbow (11) in other end of 6-inch section. Se-
cure with worm clamps.

8.

Install 45-inch section of hose (12) between elbow

and tee prior to Quick-Fill inlet under sprayer tank.
Secure with worm clamps.

9.

Mount driveline shield (13) onto driveline-bearing

mount using 5/16-inch flange bolts.

10. Mount torque-arm stop (14) onto left side of tongue

using u-bolt and flange nuts. Adjust stop to line up

with torque arm.

11. Tighten all hardware and clamps. Refer to opera-

tor’s manual for setup and operating instructions.

Figure 1

TA500 Assembly

17392

When you see this symbol, the subsequent instructions and
warnings are serious - follow without exception. Your life and
the lives of others depend on it!

!!