Table 1. Nuvia™ cPrime™ media technical description.

Functional group

Hydrophobic cation exchanger

Base matrix composition

Macroporous highly crosslinked
hydrophilic polymer

Particle size

70 µm ± 10 µm

Dynamic binding capacity*

≥ 40 mg/ml

Ligand density

55–75 µeq/ml

Recommended linear flow
rate range

50–600 cm/hr

Pressure vs. flow
performance**

Under 2 bar @ a flow rate of 600
cm/hr

pH stability

2–14 short term
3–13 long term

Chemical stability

1.0 N NaOH, 1.0 N HCl, 25%
HOAc, 8 M Urea, 6 M Gu-HCl,
6 M KSCN, 3 M NaCl, 1% Triton
X-100, 2% SDS + 0.25 M NaCl,
20% ethanol, 70% ethanol, 30%
isopropanol

Shipping solution

20% ethanol

Storage conditions

20% ethanol

Shelf life***

5 yrs

* at 10% breakthrough hIgG.

** 20 cm X 20 cm packed bed (1.17 compression factor).
*** Stored at room temperature in 20% ethanol under accelarated
conditions.