Program memory, Automatic program memory reallocation, Two-byte program instructions – HP 15c User Manual

Page 218

Advertising
background image

218 Appendix C: Memory Allocation

Your very first program instruction will commit R

65

(all seven bytes) from

an uncommitted register to a program register. Your eighth program
instruction commits R

64

, and so on, until the boundary of the common pool

is encountered. Registers from the data storage pool (at power-up, this is R

19

and below) are not available for program memory without reallocating
registers using m %.

Two-Byte Program Instructions

The following instructions are the only ones which require two bytes of
calculator memory. (All others require only one byte.)

´ b . label

´ > {0 to 9}

t . label

´ X {2 to 9, .0 to .9}

| " (n or V)

´ e {2 to 9, .0 to .9}

|F (n or V)

´ I {2 to 9, .0 to .9}

| ? (n or V)

O {+, -, *, ÷}

´ • (n or V)

l

{

+, -, *, ÷}

´ i (n or V)

O > {A to E}

´ ^ (n or V)

O

{

A to E, %} in User

mode

´ _

l {A to E, %} in User
mode

´ f

O | %

l | %

Memory Requirements for the Advanced Functions

The four advanced functions require temporary register space from the
common register pool.

Function

Registers Needed

_

f

5
23

23 if executed

together

Complex Stack

5

Matrices

1 per matrix element

Advertising