10

I N S T A L L A T I O N

VENT CAP

1. Remove the threaded plug from the pump tank.

2. Install the vent cap.

NOTE: Never run the operator without the vent cap installed.

LIMIT SHOES

NOTE: The limit shoes are slotted, so minor adjustments may be
made later for the fine tuning of the fully open and close
positions. Also, note that the limit switches themselves may be
slightly adjusted up or down.

1. Cut wire ties to release limit switch levers and RPM assembly

to the up right position. These items are held down by wire ties
to facilitate for initial gate installation.

2. Manually open the gate to the full position.

3. Locate the open limit switch lever and mark its position.

4. Manually close the gate to the full close position.

5. Locate the close limit switch lever and mark its position on the

drive rail.

6. Manually open the gate about halfway. Measure and drill holes

to mount limit shoes

7. Secure both limit shoes to underside of drive rail.

NOTE: It is highly suggested that gate stops be installed to the
gate at the fully open and closed positions. See next page for
installation instructions.

Remove Bolt To
Take Cover Off

Loosen Screw To
Remove Cover

Important: Do Not
Use Cover Handles
To Move Unit

Threaded
Plug

Vent Cap

Tank

Mark Centerline

Top
View

Top
View

Side
View

Limit Switch

Mark Centerline

Drive Rail

RPM Assembly

Limit Switch

Limit Shoe

Centerline Marks

2"

1-1/16"

3"

2"

3"

9/32" Dia.
Holes

Bottom of
Drive Rail

Washer
and Nut

1/4"-20 Screw