GL BOARD FEATURES

DIAGNOSTICS (LEDS AND CODES)

There are three diagnostic LEDs. Two red LEDs (OL, CL) are
indicators for the open and close limits. The LEDs are illuminated
when the limit switch contacts are closed.

The third amber LED (DIA) is used to blink out diagnostic codes.
The number is the count of the number of times the LED is on in
an 8 second period. The LED is on for approximately 1/2 second
and repeats every second until the number is reached. There will
be a pause following each pulse cycle (1-6 pulses) to differentiate
between the different diagnostic codes.

LED Code

Diagnostic Meaning

Cleared By

Flashed

OFF

Normal operation

N/A

1

Single entrapment sensed

Control Input

2

Double entrapment

Hard Input*

3

Failed or no RPM sensor (Hall effect)

Removal of problem

4

Exceed maximum motor run time

Hard Input*

5

Limit fault

Control Input

6

Loss of communications between master and second during run mode

Removal of problem

On No Flash

Motor not learned

Completion of Motor Learn Routine

*Hard inputs include open override, close override and stop inputs.

T R O U B L E S H O O T I N G

LED

LED NAME

DESCRIPTION

RELAY DRIVE TROUBLESHOOTING LEDS

There are 5 troubleshooting LEDs on relay drives K1 through K5. These
LEDs will be illuminated when the microcontroller relay drive is activated.

D6

Contactor A

On when Contactor A is activated

D5

Contactor B

On when Contactor B is activated

D4

SAM

On when SAM relay is activated

D3

Lock

On when Mag Lock relay is activated

D2

Alarm

On when Alarm Relay is activated

TROUBLESHOOTING LEDS

There are 9 troubleshooting LEDs.

LED

LED NAME

DESCRIPTION

D11

Radio

On when Radio switch is activated

D13

Shadow

On when Shadow Loop is activated

D15

Hard Close

On when Close switch is activated

D17

Stop

On when Stop switch is not activated

D19

Soft Open

On when Open switch is activated

D21

Hard Open

On when Open switch is activated

D24

Interrupt Loop

On when Interrupt/Safety Loop activated

D29

Obstruction Open

On when Edge is activated or when Photo Eye
Beam is broken

D31

Obstruction Close

On when Edge is activated or when Photo Eye
Beam is broken

Max

Min

Force Control