7: From the end of the out rigger arm, mark the point where
the

to be shortened. (Optional)

8: Cut at the marked point with a hacksaw.

9: Clean the inside and the outside burrs where cut.

out rigger arm needs

7

8

D

LENGTH(L) (H) FOR 30° (H) FOR 45° (H) FOR 60°

36"

24"

12"

21"

14"

7"

36"

24"

12"

62"

42"

21"

10: The cable post should be installed above the power feed
canopy so that there is a minimum of a 30° angle between
the out rigger arm and the aircraft cable to properly lock
the aircraft cable in position.

11: Use the tables below to determine the cable post position
relative to the out rigger arm for various angles.

ANGLE

EQUATION FOR HEIGHT (H)

30°

45°

60°

H = 0.6 x L

H = L

H = 1.7 X L

ANCHOR

WALL

14

13

12: Mark the cable post location on the wall above the canopy.

Using a hammer tap in the anchor on the marked

location up to the threaded portion.

14: Screw in the threaded portion of the anchor with a Phillips
screwdriver.

(See table above for measurements).

13: