17: Insert the coaxial cable into the coaxial connector until the wires of the center conductor are visible through the M3 set
screw hole.

NOTE: Ensure that the split in the ferrule is aligned 90° from the M4 set screw (see inset).

COAXIAL
CABLE

17

CONNECTOR
ASSEMBLY

FERRULE

CONNECTOR
ASSEMBLY

COAXIAL
CABLE

P

COAXIAL
CONNECTOR
COVER

BRAIDED
WIRE

FERRULE

15

16

15: Slide the connector cover over the coaxial cable.

16: Place the ferrule over the braided wire of the coaxial cable.

18: Use the provided 1.5mm Allen wrench to replace and
securely tighten the M3 set screw.

19: Use the provided 2mm Allen wrench to securely tighten the
M4 set screw until it squeezes the wire ferrule tightly to the
coaxial cable.

20: Replace the coaxial connector cover and tighten into
place.

1.5MM ALLEN
WRENCH

18

CONNECTOR
ASSEMBLY

COAXIAL
CABLE

2MM ALLEN
WRENCH

19

CONNECTOR
ASSEMBLY

COAXIAL
CABLE

M3 SET
SCREW

M4 SET
SCREW

20

COAXIAL