NOTE:

the steps below and refer to the "Indoor Installation Using
Magnetic Remote Transformer" section.

If using a magnetic transformer to power the fixtures omit

G

NOTE:

Use only octagon boxes to install the trim housings indoor.

1: Install an electrical box onto the wall or post next to the
panel to fit the LED power supply (TE-60L-12) and to branch
the power to all octagon electrical boxes.

2: Install conduit and run 120 volt power wires from the panel
to the branching electrical box.

1: Install the magnetic remote transformer to an accessible
location.

2: Refer to the instructions supplied with the remote
transformer to run the power from the panel to the remote
transformer.

Indoor Floor Installation Using an Electronic LED
Power Supply (TE-60L-12)

Indoor Floor Installation Using a Magnetic Remote Transformer

PANEL

OCTAGON ELECTRICAL BOX

1

WALL

BRANCH ELECTRICAL BOX

H

MAGNETIC REMOTE
TRANSFORMER

1

WALL

5

PANEL

2

12VAC

120VAC

3: Install conduit(s) from the branching electrical box to all
octagon fixture electrical boxes.

4: Run proper wire sizes from branching electrical box to all
fixture electrical boxes using the "Wire Size Chart" on page 6.

5: Follow steps 5 through 8 on page 1 using drawing B to
connect the wires to the power supply.

NOTE:

be considered when positioning the octagon boxes between the
joists.

Subfloor, floor, and Port trim housings (2.4") heights must

NOTE:

be considered when positioning the octagon boxes between the
joists.

Subfloor, floor, and Port trim housings (2.4") heights must

3: Install an electrical box onto the wall or ground next to the
octagon fixture electrical boxes to branch the power. Connect
a conduit coming from the remote transformer to branching
electrical box.

4: Install conduit(s) from the branching electrical box to all
octagon electrical boxes.

5: Run proper wire sizes from branching electrical box to all
octagon boxes using the "Wire Size Chart" provided with
remote magnetic transformer. Wire the transformer wires
parallel to the fixture wires. (See using diagram on page 6).

12VAC

120VAC

4

2

3

4

BRANCH ELECTRICAL BOX

3

JOIST

JOIST