9: Loosen the four #8-32 screws on the front of the housing.

10: Remove the trim and cover from the housing.

TRIM

9

COVER

#8-32 SCREW

10

11: Remove a knock out to install the power line conduit.

12: Install the conduit and run the power line wires to the
housing.

13: (OPTIONAL)-If using slave housings (Maximum 5 Slave
Housings), repeat step 1 through 10 on pages 1 and 2 for
each slave housing; run conduits for the low voltage wires
in sequence from the master housing and slave housing to
the adjacent slave housing .

14: Make sure that the housing is grounded in accordance
with local electrical codes.

15: Connect the transformer white wire to the power line
neutral wire with a wire nut.

16: Connect the black thermal protector wire to the power line
hot wire with a wire nut.

17: The transformer black wire is connected by default to the
other wire of the thermal protector.

18: If using slave housings, then follow the "Slave Step Kit
Wiring" steps; otherwise follow "Install the Drywall, Trim &
Lamp" steps on page 4.

THERMAL
PROTECTOR

TRANSFORMER

E

14

15

16

NOTE:

Maximum 5 Slave step kits can be powered from a master

step kit.

17

12

13

OPTIONAL CONDUIT
TO SLAVE HOUSING

5:
be mounted.

6: Place the adjustable mounting bars between the studs.

7: Make sure the lips on the adjustable mounting bars are
against the studs. Secure the adjustable bars to the studs
with the provided eight #8 screws.

8: Slide the housing to desired position. If necessary loosen the
wing nuts to ease the sliding. After the desired position is
achieved tighten all the wing nuts.

Select the location between the two studs for the housing to

NOTE:

The adjustable mounting bars mount to studs that are

spaced 16" to 24" apart.

C

STUD

ADJUSTABLE
MOUNTING BAR

7

6

#8 SCREW

7

7

7

8

2

HOUSING

Advertising