Edge Lighting PSB-30W-12VDC, 30 Watt 12 Volt DC Power Supply User Manual
Page 6
M
"N" White
"L" Black
" " GREEN
White +
Black -
M
N
ELECTRICAL BOX
CONDUIT
9
8
CONTROLLER
CONTROLLER
POWER SUPPLY
DMX CABLE (BELDEN #9841)
"N" White
"L" Black
" " GREEN
White +
Black -
NOTE: Use a deep double gang box to fit the controller
and controller power supply (OT-20-120-240-245
recommended).
3
7
6
5
3: Connect one end of a red wire to "VDC+" of the controller
terminal and the other end of the red wire to the "+24VDC"
of the power supply terminal.
4: Connect one end of a black wire to "Ground" of the controller
terminal and the other end to the "-24VDC" of the power
supply terminal.
5: Run the black and white line voltage wires coming from
the controller power supply to the power supply case.
6: Connect the white wire to "N" terminal of the controller
power supply.
7: Connect the black wire to "L" terminal of the controller
power supply.
8: Install conduits from controller, main panel (line voltage),
and soft strip to power supply.
9: Run proper DMX cable (Belden #9841 recommended)
with three data wires from controller to the power supply
box.
NOTE: Refer to the "Configuring DimWheel" & "Operating
DimWheel" on page 8 & 9 to properly operate the controller.
4
O
13
11
EXT in-
EXT in+
VDC-
VDC+
DMX in +
DMX in -
DMX in
shield
LEDSync
out +
LEDSync
out-
LEDSync
out shield
12
CONTROLLER
10: Install a red wire from the power supply "+V" terminal to
DVR-RGB-60 "VDC+" red terminal and a black wire from
power supply "-V" terminal to DVR-RGB-60 "VDC-" blue
terminal.
11: Connect one end of a data wire (blue with white stripes
wire) to controller "LEDSYNC OUT–" terminal. Connect the
other end into the DVR-RGB-60 "DMX in –" terminal.
12: Connect one end of a data wire (white with blue stripes
wire) to controller "LEDSYNC OUT+" terminal. Connect the
other end into the DVR-RGB-60 "DMX in +" terminal.
13: Connect one end of a data wire (bare shield wire) to
controller "LEDSYNC SHIELD" terminal. Connect the other
end into the DVR-RGB-60 "DMX in shield" terminal.
10
"N" White
"L" Black
" " GREEN
White +
Black -
P
M
CONDUIT
15
16
17
14: Run the line voltage power wires into the power supply.
15: Connect the hot power wire to black power supply wire
marked "L" and black wire coming from the controller
power supply with a wire nut.
16: Connect the neutral power wire to white power supply wire
marked "N" and white wire coming from the controller
power supply with a wire nut.
17: Make sure the green transformer wire is grounded in
accordance with local electrical codes.
6
DO NOT
USE
NOTE: "DMX in+", "DMX in-", "EXT in+" & "EXT in-",
controller terminals are not used on controller.