FASS FA F16 220G User Manual

Page 10

Advertising
background image

M.

Carefully reinstall install pick up module making sure the leveling arm is not obstructed by the suction
tube. Reinstall factory lock ring. Push one end of fuel line onto ‘S’ port of suction tube assy. Route
fuel line over frame. Do not cut at this time. Reinstall fuel tank making sure to reconnect factory lines
and electrical connections. Torque hanger bolts to factory specifications.

K.

Place the bulk head assembly into the drilled hole, take measurements so
the bottom of the suction tube is only 1/8” (no more than 2 quarters
stacked) from the bottom of the fuel tank. Using a razor knife, make multi-
ple cuts to insure proper length, it is easy to shave the suction tube with the
razor. It is more efficient to cut the tube too long and then correct to
proper length than it would be to cut too short.

L.

With proper length being obtained place the assembly into the drilled hole
securing the assembly using the lock washer & nut. Tighten Nut. Loctite
may be applied to the threads of the BHF-1002 for added insurance.

I.

Drill a 1 3/8” hole, catching all debris. De-bur hole and remove any
missed debris in the fuel tank.

J.

VERY IMPORTANT:

Support fuel tank on both ends allowing the natu-

ral formation of the tank to take place. Failure to perform this step can and
will create an issue with less usable fuel!

H.

Before drilling marked location, clean area of debris. Using the photo dou-
ble check area selected for any interference including the fuel level arm.

Advertising