FASS FA F16 220G User Manual

Page 12

Advertising
background image

E.

Slid the FASS pump into mounting brackets with the weep hole facing down. Torque (4) bolts to 110
inch pounds.

D. Using thread tape, install the 2 10-300 into the “T” & “E” ports. Torque to 40 ft./lbs. Connect the male

end of the wire harness to the female electrical connector on the FASS pump. Reconnect the battery.
Turn key to the “On” position. With the FASS pump on, squirt a liberal amount of WD-40 or other
lubricant into the “T” port. This procedure will “wet” the Gerotor and allow for better suction during
initial priming.

Note: Do Not Put Thread Tape on Flare of Fitting

Advertising