9 connection diagram and pin assignment, 10 grounding concept – Baumer BA OADM20I6 OADM21I6 User Manual
Page 56
BA_OADM20I6_21I6_most.doc
56/88
Baumer
26.03.13
Frauenfeld, Switzerland
9 Connection diagram and pin assignment
Connection diagram
Pin assignment
If external Teach-In option is not used, the Teach-In wire must be attached to GND.
10 Grounding concept
For maximum EMC protection and reliable application, use a shielded cable. Also, the sensor has to be
grounded.
We recommend the grounding concept as shown in the picture. Ground the sensor with a toothed washer
between the screw head and the sensor.
If you prefer another grounding concept please contact your Baumer electric sales staff.
11 Service notes
The OADM requires no maintenance apart from keeping the front windows clean. Dust or fingerprints can
impair the sensor function. It is normally sufficient to wipe the windows dry with a clean (!), soft cloth. Alcohol
or soapy water may be used for heavy soiling.
●
= electrical connection
Power-supply
A/D Converter
OADM