Sas 2.5-inch peripheral interposer board, Peripheral interposer board connectors – Dell PowerEdge 6850 User Manual

Page 19

Advertising
background image

SAS Information Update

17

Installing a 2.5-Inch SAS Backplane

1 Install the SAS backplane:

a

Carefully lower the backplane into the system as shown in Figure 1-9, angling the top of the
backplane slightly toward the back of the system. Be careful to avoid damaging components
on the face of the board.

b

Slide the retention slots on the backplane over the retention hooks on the chassis.

c

Slide the backplane downward until the blue retention tab snaps into place.

2 Connect the SAS and backplane power cables to the back of the SAS backplane.

Secure the SAS cable(s) in the clip that is attached to the fan-3 air guard. See Figure 1-8.

3 Install the SAS hard drives in their original locations. See "Installing a Hot-Plug Hard Drive"

on page 10.

4 Install the optical drive/diskette drive carrier.

Slide the drive carrier into its drive bay and press in the release latch. See the Installation and
Troubleshooting Guide.

5 Install the cooling shroud. See "Installing the Cooling Shroud" the Installation and Troubleshooting

Guide.

6 Close the system. See "Closing the System" in the Installation and Troubleshooting Guide.
7 Reconnect the system to its electrical outlet and turn the system on, including any attached

peripherals.

SAS 2.5-Inch Peripheral Interposer Board

In addition to the backplane, systems with 2.5-inch drives also have a peripheral interposer board, which
contains some of the connectors that are on the 3.5-inch board and a backplane power connector.

Peripheral Interposer Board Connectors

Figure 1-10 presents a front view of the peripheral interposer board.

Advertising