Dell PowerEdge 2850 User Manual

Page 11

Advertising
background image

Information Update

9

E0D76

BP DRIVE n
1x2 DRIVE FAIL n
SCSI CONNECTOR

Faulty or improperly installed
hard drive or RAID controller.

See "Troubleshooting SCSI Hard
Drives" "Troubleshooting a RAID
Controller Card, " and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide.

EB107

PROC BUS ERR

PROC INIT ERR

PROC PROTOCOL

ERR

Faulty or improperly installed
microprocessor or system board.

See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.

EB107

PCIE FATAL ERR

CHIPSET ERR

Faulty or improperly installed
PCI-e card.
Faulty or improperly installed
riser card.
Faulty system board.

Remove and reseat the PCI-e
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" in your
Installation and Troubleshooting
Guide.

Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide.

If the problem persists, the riser
card or system board is faulty.
See "Getting Help" in your
Installation and Troubleshooting
Guide.

EB107

MEMORY MIRRORED

Memory mirroring enabled.

Information only.

EB107

MEMORY SPARED

Memory spare bank enabled.

Information only.

EFFF2

ROMB PRESENCE

Integrated RAID controller is
activated.

Information only.

IB110

SBE LOG DISABLED

LOGGING DISABLED

Information only.

IS000

INTRUSION

System cover has been removed.

Information only

NOTE:

For the full name of an abbreviation or acronym used in this table, see the "Glossary"

in your User’s Guide.

Table 1-4.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions

Advertising