Dell PowerEdge 2850 User Manual

Page 9

Advertising
background image

Information Update

7

E0000

OVRFLW CHECK LOG LCD overflow message.

A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.

Check the SEL for details
on the events.

E0119

TEMP AMBIENT

TEMP BMC

Ambient system temperature is
out of acceptable range.

See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.

E0119

TEMP RISER

Riser card is out of acceptable
temperature range.

See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.

E0212

VOLT PG n

System power supply is out of
acceptable voltage range; faulty
or improperly installed power
supply.

See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide.

E0212

VOLT BATT ROMB

Faulty RAID battery.

Replace the RAID battery.
See "Activating the Optional
Integrated RAID Controller"
in your Installation and
Troubleshooting Guide.

E0212

VOLT BATT CMOS

Faulty system battery.

Replace the system battery.
See "System Battery" in your
Installation and Troubleshooting
Guide.

E0212

VOLT RISER 5V

VOLT RISER

Riser card voltage is out of
acceptable range; faulty or
improperly installed power
supply; faulty system board.

Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide. If the
problem persists, see "Getting
Help" in your Installation and
Troubleshooting Guide.

E0412

RPM FAN n

FAN REDUNDANCY

LOST

Specified cooling fan is faulty,
improperly installed, or missing.

See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.

Table 1-4.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions

Advertising