Table 1 — Condenser Unit Application

UNIT

50BZ

09BY

006

008

012

014

016

024

006

S

008

S

012

O

S

014

O

S

016

O

S

024

O

S

LEGEND

S — Standard
O — Optional
NOTE: Contact your local representative for use with reciprocating air-cooled chillers and other compressor-bearing unit combinations.

Table 2 — Physical Data

UNIT 09BY

006

008

012

014

016

024

NOMINAL TONS

5

7

1

2

10

12

15

20

OPERATING WEIGHT (Lb)

267

357

441

471

837

970

REFRIGERANT

R-22

Number of Circuits

1

1

2

2

2

3

Minimum Charge (Lb/Ckt)

6

11

6

6/11

11

11

Optimum Charge (Lb/Ckt)

8.38

14.5

8.38

8.38/14.5

14.5

14.5

Storage Volume Ft

3

/Ckt)

0.31

0.47

0.31

0.31/0.47

0.47

0.47

Holding Charge

Nitrogen Charge

CONDENSER FAN

Belt Drive, Centrifutal

Nominal Airflow (Cfm)

3000

4500

6000

7200

9000

12,000

Cfm Range

2000-4500

3400-6400

4500-7000

6000-7600

6700-9750

7500-11,000

Quantity

2

2

2

2

2

2

Size (in.)

8.8 Ч 8.8

11.0 Ч 11.0

11.0 Ч 11.0

11.0 Ч 11.0

12.4 Ч 12.4

14.0 Ч 14.0

Pulley Size (in.)

5

11

16

7

5

8

6

5

8

6

11

16

10

13

11

16

Motor Pulley Range (in.)

4

3

16

-5

1

2

4

3

16

-5

1

2

4-5

4-5

4

3

4

-6

5

3

8

-6

5

8

Rpm Range

1365-1566

960-1260

1106-1455

1045-1306

840-1050

686-847

Maximum Fan Rpm

1705

1365

1365

1365

1210

955

Belt Quantity...Size

1...A41

1...B46

1...B45

2...A45

2...B88

3...B90

Pulley Center Line Distance (in.)

11.2/12.6

13.6/15.0

13.6/15.0

13.6/15.0

32.6/33.8

30.0/30.7

Fan Shaft (mm)*

20

25

25

25

25

30

Motor Shaft (in.)

7

8

1

1

8

1

1

8

1

1

8

1

1

8

1

3

8

Motor Hp...Type

2...TEFC†

3...TEFC

3...TEFC

5...TEFC

5...TEFC

10...TEFC

Motor Frame Size

145T

182T

182T

184T

184T

215T

Maximum Motor Hp

3

5

5

5

5

10

CONDENSER COIL

3

8

-in. OD Enhanced Copper Tube, Aluminum Fin

Rows...Fins per in.

4...14

5...14

5...14

5...14

4...15

5...15

Face Area (sq ft)

6.33

8.75

10.12

11.45

19.38

19.38

CONNECTIONS

Hot Gas

Quantity

1

1

2

2

2

3

Size (in.)

1

2

1

2

1

2

1

2

1

2

1

2

Liquid Line

Quantity

1

1

2

2

2

3

Size (in.)

1

2

1

2

1

2

1

2

1

2

1

2

Condensate Drain (in.)

3

4

FPT

CONTROLS

24-V Control Fan Contactor Provided in Unit

*Metric size.
†TEFC — Totally Enclosed Fan Cooled.

NOTE: Optimum charge is based on 15° F subcooling. Minimum charge is based on 5° F subcooling.