Cecilware BC301-IT User Manual

Page 19

Advertising
background image

19

5) CHECK DISPENSE VALVES FOR LIME BUILD-UP (

Located inside top cabin

)

Drain The Water Tank To Just Below The Level Of The Dispense Valves.

Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown.
Replace The Assembly As Needed.
Replace The Valve Into The Tank And Refill tank.

a) The

SINGLE DISPENSE VALVE

is factory adjusted to dispense

0.5 oz./sec. of water during the brew cycle (spray duration).

b) The

DOUBLE/ DILUTION DISPENSE VALVE

is factory adjusted,

on both sides, to dispense 0.22 oz./sec of water during dilution cycle.


TO ADJUST WATER FLOW RATE:

Locate adjustment screw on valve (as show here).

Using an Allen Key or a flat screwdriver, rotate ¼ turn at a time,

Clockwise (CW) to decrease water flow rate or
Counter-Clockwise (CCW) to increase water flow rate.

Check water flow output after each ¼ turn.



































Advertising