Cecilware BC301-IT User Manual

Page 9

Advertising
background image

9

INFUSION TIME

INFUSION TIME

## SECONDS

Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water into
the grinds during the Pre-Infusion process.
SOAK TIME

SOAK TIME

## SECONDS

Description – The Soak Time is the amount of time that the system will wait between the end of the hot
water infusion period and the beginning of brewing.
PULSE BREW

PULSE BREW

ON/OFF

Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing
(pulsing) hot water.
PULSE ON TIME

PULSE ON TIME

## SECONDS

Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot
water during a Brew Cycle.
PULSE OFF TIME

PULSE OFF TIME

## SECONDS

Description – The Pulse OFF Time is the amount of time that the system will wait between hot water
dispenses during a Brew Cycle.
DRIP TIME

DRIP TIME

### SECONDS

Description – The Drip Time is the amount of time that the system will wait after the completion of the hot
water dispense before signaling the end of the Brew Cycle. This allows time for any water remaining in
the funnel to drain out.
DILUTION

DILUTION (36)

ON/OFF

Description – The Dilution feature gives the user the ability to add hot water directly to the brew without
passing through the grinds. This option is only available in models with a 36-Cup Dispense Key.
DILUTION PERCENT

DILUTION PERCENT

## %

Description – The Dilution Percent is the percentage of the total volume of the brew (Brew Size) that is
diluted
DILUTION FILL CONSTANT

DIL FILL CONST

#.## OZ/SEC

Description – The Dilution Fill Constant is the exact value of the rate at which hot water is dispensed from
the Dilution Solenoid Valve during each Brew Cycle. The accuracy of this value is crucial to the proper
operation of this system.
This value is directly related to the orifice size of the Dilution Solenoid Valve. A
simple method for calibrating the Dilution Solenoid Valve has been provided in Normal Mode (see Dilution
Fill Constant Calibration section of Normal Mode Descriptions).
DILUTION DELAY

DILUTION DELAY

### SECONDS

Description – The Dilution Delay is the amount of time the system waits from the start of Brewing to the
start of Dilution.
WATER TEMPERATURE

WATER TEMP

### °F

Description – The Water Temperature is the required (set point) temperature of the water in the reservoir
tank.