MODES OF OPERATION – DESCRIPTIONS


Initialization Mode:

The following screen signifies the presence of this mode:

CECILWARE

&&&&& REV #.#

Description

– This mode is active only during the first few seconds after “power-on”. The purpose of

the Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision
Number (depicted by “#.#”).

Normal Mode:

The following screen signifies the presence of Normal Mode:

SSSSSS DDD K
SSSSSS HH:MMP

Description

– Normal Mode is active immediately after Initialization Mode. The left half of the screen

displays the present System State (depicted by “S”). Refer to the subsequent State Descriptions in this
section for more information on System States. The right half of the screen displays the present day of
the week (depicted by “D”), the present time (depicted by “HH”:”MMP”), and the current KeyLock
Status (depicted by “K”). The day of the week is identified using familiar three letter abbreviations.
The time is identified using hours and minutes along with a “AM/PM” indicator. If KeyLock is enabled
the” KL” symbol will be present. Enabling KeyLock will prevent unauthorized users from operating the
unit. Refer to the Service Mode Descriptions for more information on the KeyLock function.

Filling State

FILLING DDD K

TANK HH:MMP

Description

– This screen is displayed during the initial filling of the water tank (first fill). Once the

water in the reservoir tank has reached the appropriate fill level this screen is retired.

Heating State:

HEATING DDD K

TTTF HH:MMP

Description

– This screen is displayed when the present water temperature is below the Lockout

Temperature Set Point. The actual water temperature is displayed in the lower left-hand portion of the
screen (depicted by “TTTF”). If the Brew Key is depressed while in the Heating State the system will
advance to the Waiting State. If the Brew Key is depressed for more that three seconds the Waiting
State is bypassed and the system will advance to the Brewing State.

Waiting State

WAITING DDD K

TTTF HH:MMP

Description

– This screen is displayed when the operator presses the Brew Key while the system is in

the Heating State. The actual water temperature is displayed in the lower left-hand portion of the
screen (depicted by “TTTF”). The Brew Key LED will blink in this state. Once the water temperature
reaches the Lockout Temperature Set Point the system will automatically advance to the Brewing
State.

Pressing the Brew Key or the Cancel Key while in the Waiting State will cause the system to revert
back to the Heating State.

Ready (to Brew) State

READY DDD K

TO BREW HH:MMP

Description –

This screen is displayed when the system is ready to begin a Brew Cycle. Pressing the

Brew Key while in the Ready State will advance the system to the Brewing State (i.e. begin a Brew
Cycle).