Rack Installation Guide

1-13

6

To remove the tower system front panel (see Figure 1-9):

a

Position the system so that the front panel extends about 2.5 centimeters (1 inch)

beyond the edge of the table or work surface.

b

Remove the 14 4-40 x 0.25-inch pan head black T-10 Torx screws that secure the

tower front panel to the chassis.

c

Remove the front panel from the system chassis, taking care to avoid damaging

the five plastic light pipes that extend through the front panel.

Installing the Rack Front Panel

1

Position the rack front panel on the front of the system chassis, using care to install the

five light pipes in their holes in the front panel.

NOTE: In the next step, start all 14 T-10 Torx screws in their holes before tightening any

of the screws to ensure proper alignment.

2

Secure the rack front panel to the chassis with the 14 T-10 Torx screws that you

removed in step 6 of the last procedure, “Removing the Bezel, Drives, Covers, and

Front Panel” (see Figure 1-9).

3

Reinstall the power and cooling modules (if they were removed).

NOTE: Do not install the hard drives until the next procedure, “Installing the System in

the Rack,” is completed.