Dell OptiPlex 330 (Late 2007) User Manual

Page 55

Advertising
background image

Quick Reference Guide

55

C M O S

CHECKSUM

ERROR

Possible motherboard failure or RTC battery low.

Replace battery.

C P U

FAN

FAILURE

CPU fan failure. Replace the CPU fan.

D

ISKETTE

DRIVE

0

SEEK

FAILURE

A cable may be loose, or the computer

configuration information may not match the hardware configuration. Check cable
connections.

D

ISKETTE

READ

FAILURE

The floppy disk may be defective or a cable may be

loose. Replace the floppy disk/check for a loose cable connection.

H

ARD

-

DISK

DRIVE

FAILURE

Possible hard disk drive failure during HDD

POST. Check cables /swap hard disks.

H

ARD

-

DISK

DRIVE

READ

FAILURE

Possible HDD failure during HDD boot test.

K

EYBOARD

FAILURE

Keyboard failure or keyboard cable loose.

N

O

BOOT

DEVICE

AVAILABLE

The system cannot detect a bootable device or

partition.

• If the floppy drive is your boot device, ensure that the cables are connected and

that a bootable floppy disk is in the drive.

• If the hard drive is your boot device, ensure that the cables are connected and

that the drive is installed properly and partitioned as a boot device.

• Enter system setup and ensure that the boot sequence information is correct.

N

O

TIMER

TICK

INTERRUPT

A chip on the system board might be

malfunctioning or motherboard failure.

N

ON

-

SYSTEM

DISK

OR

DISK

ERROR

Replace the floppy disk with one that has

a bootable operating system or remove the floppy disk from drive A and restart the
computer.

Advertising