22. Turn on gas supply and operate valve with remote

control as needed to indicate gas pressure. The
manifold pressure for LP should be approximately
10.0” wcp.

CAUTION: Turn off the valve and gas supply
before removing test port adaptor and replac-
ing plug.

23. After test, remove adaptor and replace plug.
24. Turn on gas supply and check that plugs are tight

and leak free.

25. Follow instructions in Homeowner’s Manual to

re-assemble brick panels, logs, lava rock, volcanic
rock, embers and andirons.

26. Replace glass frame.
27. Conversion complete.

Table 1 DVT38S2 Injector Orifice Size Matrix

Conversion to LP

KiT #

Burner

20012368

Burner

Housing/

Burner

Burner

Input (BTU/hr)

Model

Housing

Part #

Pilot*

Part #

Tube

Part #

Tube

Part #

Min.

Max.

DVT38S2IP

#55

30000333

#54

20000130

#57

20004587

#57

20004587 38,000 56,000

(.052”)

(.055”)

(.043”)

(.043”)

Table 2 Valve Minimum Rate Screw

Model

Drill Size

Part #

DVT38S2IP

No Shank

20012264

Screw

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the pilot flame sensor
should be engulfed in the pilot flame. (Page 33, Fig. 52)
To adjust pilot burner:
1. Locate pilot adjustment screw on the valve next to

the black plastic cap. Refer to Page 35.

2. Adjust pilot screw to provide proper sized flame.

Only a small adjustment should be needed.

NOTE: Do not rotate screw excessively. Do not adjust
any other screws on the valve.