Chateau™ direct vent gas fireplace, Hearth framing and finishing, Final finishing – Vermont Casting DVT38S2IN User Manual

Page 7

Advertising
background image

7

Chateau™ Direct Vent Gas Fireplace

20011957

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12” (305 mm) or more from
the front of the fireplace. The hearth cannot exceed 1¹⁄₂”
(38 mm) in height from bottom of fireplace for ease of
door accessibility. (Fig. 4)

Cold climate installation recommendation:

When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory the outer walls be insulated to
conform to applicable insulation codes.

Hearth

Framing and Finishing

1. Choose the unit location.
2. The unit is shipped with four (4) nailing flanges

mounted near the front corners on the side with the
valve box assembly . (Fig. 4)

3. Frame the fireplace with a header across the top of

the standoff. (Fig. 5) It is very important to allow for
the finished wall face along with marble, tiles or any
other noncombustible face finish material desired
when setting the depth of the framing.

4. Attach the fireplace nailing flanges to the frame as

shown in Figure 4.

FP1357b

DVT38s2nailing flanges

3/17/04 djt

6"

(152 mm) Min.

1"

(25 mm) Min.

1���"

(38mm)

Max. Hearth Height

FP1357c

Fig. 4 Nailing flanges.

Bend

Line

5. The gas components are located in the valve box as-

sembly attached to the side of the unit.

6. The U-channel located on the top of the unit as well

as the nailing flanges on the sides that were men-
tioned in Step 1, are designed to accommodate non-
combustible board (recommended Dura-Rock). They

are positioned 1” (25mm) back from the face of the
unit. NOTE: The U-channel depth can be adjusted
by loosening the hex nut inside the channel.

If marble, tile or any other noncombustible decora-

tive face finish material is desired, a 3” (76mm) wide
noncombustible board (recommended Dura-Rock)
is to be nailed to the nailing flanges on both sides
of the unit. Also, 12” (305mm) of noncombustible
board is to be nailed to the front face of the U-chan-
nel and the top framing member above the standoff.

Combustible material can then be brought to the

outside edges of the noncombustible board installed
earlier. Any noncombustible decorative face finish
could be brought to the sides and top of the unit and
can cover the framing and sheet rock. If a decora-
tive facing is not desired, then the noncombustible
boards must be double thickness and brought flush
with the face of the unit.

Final Finishing

Noncombustible materials such as brick or tile may be
brought to the edges of the face of the appliance.

FP1467b

DVT38s2

framing

5/07 djt

1"

(25 mm)

6"

(152 mm)

Fig. 5 Fireplace framing.

FP1467b

This side of fireplace
must be facing interior
of home

Advertising