Chateau™ direct vent gas fireplace, Fireplace dimensions, Locating your fireplace – Vermont Casting DVT38S2IN User Manual

Page 5: Standard framing

Advertising
background image

5

Chateau™ Direct Vent Gas Fireplace

20011957

Y

D

A

B

C

E

Y

X

LU584

Locating unit

DVT38S2

3/17/04 djt

Locating Your Fireplace

LU584-1

Fig. 2 Locate gas fireplace.

A) Flat on wall

B) **Island

C) *Room divider

D) *Flat on wall corner E) Chase installation
Y) 6” minimum
Note (Fig. 2):
** Island (B) and Room Divider (C) installation is possible as long
as the horizontal portion of the vent system (X) does not exceed 20’
(610cm). See details in Venting Section.
* When you install your fireplace in (C) Room divider or (D) Flat on
wall corner positions (Y), a minimum of 6” (152mm) clearance must
be maintained from the perpendicular wall and the front side edge of
the fireplace.

24���"

(622 mm)

C

L

10���"

(267 mm)

3/4"

(19 mm)

C

L

51���" (1299 mm)

*

3/4" (19 mm)

34���" (876mm)

29���"

(746 mm)

32���"

(829 mm)

33���"

(854 mm)

*

49���"

(1245 mm)

1���"

(35 mm)

1/2"

(13 mm)

5/8" (16 mm)

44���" (1121 mm)

37���" (962 mm)

5���" (143 mm)

6" (152 mm)

1"

(25 mm)

*

When framing unit on outside wall, flush with the wall,

a 1/4" (6mm) clearance must be allowed on both sides and top of surround.

11957

DVT38s2 specs

5/07

Sides and Top

of Surround

C

L

25

����

(649 mm)

Glass

25

����

(649 mm)

Gas Line
Connection

15���”

(403 mm)

10����”

(262 mm)

Noncombustible Material in This Area

Fireplace Dimensions

Fig. 1 Fireplace specifications and framing dimensions for DVT38S2.

Finished Wall 24¹⁄₂” (622 mm)
for Flush Install 16” (406 mm)
I.D. Minimum Clearance to
Combustibles

Standard Framing

NOTE: Noncombustible insula-
tion may be placed behind the
facing material.

Only
Noncombustible
Material in
This Area

Exterior Side
(If installed on
outside wall)

Interior
Side

Advertising