Crestron electronic DigitalMedia Room Controller DM-RMC-100 User Manual

Page 21

Advertising
background image

Crestron DM-RMC-100

DigitalMedia™ Room Controller, CAT

1. Interface connectors for 24 A B G, COM, IR, RELAY and SENS ports are

provided with the unit.

2. HDMI requires an appropriate adapter or interface cable to accommodate a DVI

signal. CBL-HD-DVI interface cable sold separately.

3. Maximum string length for IR commands should be no greater than 40 characters.
4. To determine which is pin 1 on the cable, hold the cable so that the end of the

eight pin modular plug is facing away from you, with the clip down and copper
side up. Pin 1 is on the far left.

5. The DM INPUT port consists of two separate RJ-45 connectors, labeled D and

M. The D port carries HDMI signal. The M port carries data. Refer to the
following table for the connector pinouts.

1

8

PIN #

WIRE COLOR

PIN #

WIRE COLOR

1

Orange/White 5

Blue/White

2

Orange

6

Green

3

Green/White 7

Brown/White

4

Blue

8

Brown

6. For DigitalMedia CAT wiring, use DM-CBL DigitalMedia Cable. Up to two DM

Repeaters (model DM-DR, sold separately) may be required. Refer to the latest
version of the Creston DigitalMedia Design Guide (Doc. 4789) for complete
wiring guidelines.

7. Refer to the following table for the 24 A B G port connector pinouts.

24 A B G

PIN #

SIGNAL

DESCRIPTION

WIRE COLOR

24

24V DC

DC Power

Red

A

DMNet+

DMNet

Orange

B

DMNet-

DMNet

Gr

ay

G

Ground

DC Ground

Black

8. DMNet wiring is not compatible with Cresnet

®

wiring. DMNet wiring cannot be

daisy chained.