Troubleshooting

29

BIOS Error Messages

Configuration Utility Options Image

checksum error

Failed to properly read Configuration Utility options from
flash. Reboot the system and try again. If the problem
persists, re-flash the BIOS/firmware on the adapter.

Configuration Utility Options Image

error

Failed to properly read Configuration Utility options from
flash. Reboot the system and try again. If the problem
persists, re-flash the BIOS/firmware on the adapter.

Configuration Utility Options Image

not found

Failed to properly read Configuration Utility options from
flash. Reboot the system and try again. If the problem
persists, re-flash the BIOS/firmware on the adapter.

Can't load default Configuration

Utility options

Failed to allocate memory for Configuration Utility options
structure.

An error occurred while writing

non-volatile settings

An error occurred while writing one or more settings to the
firmware.

Table 6-4.

BIOS Error Messages

Message

Meaning and Suggested Solution

Press <Ctrl><C> to Enable BIOS

When the BIOS is disabled, you are given the option to
enable it by entering the configuration utility. You can change
the setting to Enabled in the configuration utility.

Adapter at Baseport xxxx is not

responding where xxxx is the

baseport of the controller

If the adapter does not respond for any reason but is detected
by the BIOS, it displays this warning and continues. Shut
down the system and try to reseat the adapter. If this message
appears again, see "Getting Help" on page 35.

Following SAS targets are not

responding...

When the BIOS determines that previously configured physical
disks are not connected to the adapter, the BIOS displays this
warning. The system continues to boot. See "Physical Disk
Related Issues" on page 28 for troubleshooting tips.

Unsupported Disk Drive

The physical disk present is not supported by the adapter.

Adapter configuration may have

changed, reconfiguration is

recommended!

Press CTRL-C to run Dell SAS 5

Configuration Utility…

This message appears when multiple SAS 5 HBA's are moved
within the system without proper boot order selection in the
system BIOS. Start the Configuration Utility and select the
boot order of the SAS 5 HBA in the system BIOS.

Initializing...

Displays while the BIOS is waiting to initialize.

Table 6-3.

Configuration Utility Error Messages (continued)

Message

Meaning and Suggested Solution

KD534bk1.book Page 29 Monday, April 2, 2007 4:37 PM