Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions

5

1.

Using a Phillips-head screwdriver, turn the two captive screws counter-
clockwise to release the power supply from the power-supply bay.

2. Holding the handle on the power supply, carefully pull the power supply out

of the power-supply bay (see Figure 5).

NOTE: The power-supply handle is provided to ease the task of pulling the
power supply free from the bay. Do not use the handle to carry the Dell
PowerVault 2xxS storage system.

Figure 5. Removing a Power Supply on a Redundant System

3. Repeat steps 1 and 2 to remove the remaining power supply.

Remove the Cooling Fans

NOTICE: In a nonredundant system, note that the cooling-fan blank

is located in the right cooling-fan bay. During the installation proce-

dure (found later in this document), you must return the cooling-fan

blank to the right cooling-fan bay.

NOTE: A redundant storage system has three cooling fans. A nonredundant
storage system has two cooling fans and one cooling-fan blank. Because a
cooling fan and a cooling-fan blank are removed in the same manner, both
components are referred to as a cooling fan in this procedure.

To remove the cooling fans from the storage system, perform the following
steps:

1.

Using a Phillips-head screwdriver, turn the two captive screws counter-
clockwise to release the cooling fan from the cooling-fan bay.

captive screws (2)