Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions

2. Holding the captive screws, carefully pull the cooling fan out of the cooling-

fan bay (see Figure 6).

Figure 6. Removing a Cooling Fan

3. Repeat steps 1 and 2 to remove the remaining cooling fans.

Remove the Enclosure Services Modules or

Enclosure Services Expander Modules

NOTICE: In a nonredundant system, note the location of the enclo-

sure services module, the enclosure services expander module, or

the terminator blank as you remove them from the module bays.

During the installation procedure (found later in this document), you

must return the enclosure services module, enclosure services

expander module, or the terminator blank to the same module bays

from which they were removed.

NOTICE: In a redundant system, note the location of the enclosure

services or enclosure services expander modules as you remove

them from the module bays. During the installation procedure (found

later in this document), you must return these modules to the same

module bays from which they were removed.

NOTE: A redundant storage system has two enclosure services or enclosure
services expander modules. A nonredundant storage system has one enclo-
sure services module or one enclosure services expander module and one
terminator blank. Because an enclosure services module, enclosure services
expander module, and a terminator blank are removed in the same manner, all
three components are referred to as an enclosure services module in this
procedure.

To remove the enclosure services modules, perform the following steps: