Firmware requirements, Downloading firmware and drivers – Dell PowerEdge VRTX User Manual

Page 6

Advertising
background image

backplane expander board firmware, and the PowerEdge VRTX chassis infrastructure firmware. For the
latest versions of drivers and firmware, see

Downloading Firmware and Drivers

in this document.

Firmware Requirements

NOTE: Ensure that you have uninterrupted network connectivity. The update fails if the network
connectivity is interrupted during the process.

Each firmware upgrade process is described in detail in this document.

Table 1. Firmware Required for the Upgrade Procedure

Firmware

Minimum Version

File Type

Installation Time

Shared PERC 8
Device Driver for
each server module

Windows:
6.802.19.0
ESXi 5.1:

06.802.71.00

Operating
system
dependent

Up to 10 minutes.

CMC Firmware

1.30

.bin

Up to 10 minutes.
The process may take longer if you have a

secondary CMC installed. For dual CMC,

ensure two network cables are

connected.

Shared Hard Drive
Firmware

Depends on hard
drive type

.exe

Up to 2 minutes.

Chassis
Infrastructure
Firmware

1.30

.bin

Upto 25 minutes.
The process may take longer for dual

CMCs.

Shared PERC 8
Firmware

23.8.10-0059

.exe

Up to 10 minutes.
The process may take longer for updating

both the Shared PERC 8 cards.

Backplane
Expander Board
Firmware

1.02

.exe

Up to 2 minutes.

Downloading Firmware and Drivers

1.

Go to dell.com/support/drivers.

2. Enter the Service Tag for the PowerEdge VRTX system in the Service Tag or Express Service Code

box and click Submit.

3. Under Refine Your Results, select the operating system.

Ensure that you select the correct operating system.

6

Advertising